Explanation

Protecting the admin area

The admin area is guarded by one thing, the password of each account. This page explains what the kiosk checks and what it leaves to you, what a staff account can really do, why a session never ends on its own, and where the recovery PIN and emergency codes fit.

The admin area is where prices, credits, templates, the cash count, and the cloud link live. The kiosk guards it with one thing: the password of each admin account. There is no second factor, no timeout, and no lockout on a wrong password. This page explains what that means in practice and where the real protection has to come from. The steps for signing in, changing a password, and adding or removing an account are in Set up the kiosk for the first time and The admin area.

The gesture is not a secret

Five taps in the top-right corner of the welcome screen open the sign-in screen, and that fact is in this documentation. Anyone who has read it can bring up the "Admin Access" screen on any booth. That is fine: the screen gives nothing away. A wrong username and a wrong password both get the same "Invalid username or password", so a stranger cannot even learn which usernames exist. Everything rests on the password.

What the kiosk checks about a password, and what it does not

The kiosk never stores a password itself, only a salted hash of it, so nobody can read a password back, including BoothIQ support. A forgotten password is reset, never recovered; see Locked out of admin.

Beyond that the kiosk is permissive. The forced change on a factory account accepts anything typed the same way twice. Change My Password and Add User accept any password of four characters or more. The reset that follows a recovery PIN accepts anything that matches. No screen asks for capitals, digits or symbols, and no screen refuses a common word. A wrong password does not lock the account either: the screen says so and lets the next attempt in straight away, so someone standing at the booth can keep guessing for as long as they like.

That makes length the whole game. A long passphrase of several unrelated words is far harder to guess than a short password full of symbols, and it is easier to type on the kiosk's on-screen keyboard. Current guidance from NIST puts a password that stands alone at fifteen characters or more and advises against composition rules and scheduled changes. Change a password when someone who knew it leaves, or when you think it was seen, not because a date came round. Do not reuse the password of your email or your BoothIQ account: this one is typed on a large screen in a public room.

The on-screen keyboard is the other thing to keep in mind. It is big, bright, and readable from a few steps away, and the password field has a show/hide toggle. Sign in with your back to the room, or wait until nobody is close.

The factory accounts

A kiosk leaves the factory with two accounts, a main one and a staff one, on passwords that appear in BoothIQ's own material. The kiosk notices a sign-in with factory details and refuses to go further until that account's password is changed. It only does this for the account you sign in with. The other account keeps its factory password until you change it or delete it, which is why the set-up tutorial has you remove the second factory account before the booth opens. A booth with one factory account left on it is a booth anyone can change prices on.

Two kinds of account

Each account has an access level, shown as a badge at the top of the admin area: "Master Access" or "User Access". The difference is smaller than the names suggest. A User sees everything except the Subscription tab and, on the Settings tab, User Management, "Kiosk mode", and the restore from a cloud backup. Everything else is open to both: prices and mode, adding credits, recording a cash collection, uploading and removing templates, changing the Wi-Fi network, restarting the booth, and unregistering it from your account.

So a User account is a staff account, not a read-only one. Give it to someone you would trust with the cash box. Give each person their own account, because an account is the only thing you can take away from one person without touching everyone else: deleting it from User Management ends that person's access while the other passwords stay as they were. Only a Master can add or delete accounts, and the kiosk refuses to delete the account that is signed in, so the last Master cannot remove itself by mistake.

A session ends only when you end it

The admin area has no inactivity timeout. A session stays open until someone taps Exit Admin or the booth restarts. Walk away from an open admin screen and the next person at the booth has it, with no password asked. Tapping Exit Admin takes a second and puts the admin area out of reach again.

The one place the kiosk does ask again is money: Update payment card and Cancel subscription on the Subscription tab first ask for a Master username and password, because the sign-in behind the open session may be hours old. That check accepts an ordinary account password only, never an emergency code.

The recovery PIN

Every account can have a four-digit recovery PIN, set when the account first signs in. The PIN resets that account's password from the sign-in screen, through Forgot your password?, with no help from anyone. It is hashed like the password. Five wrong PINs in a minute pause that account for a minute, and the kiosk forgets the count when it restarts.

Four digits with a one-minute pause is a convenience, not a lock. The PIN is only as safe as the password it can replace, so treat it the same way: written down somewhere other than the booth, and not a year, a door code, or four of the same digit.

When every password is gone

If a password and its PIN are both lost, two kinds of one-time code open the admin area from the ordinary sign-in screen: an emergency password you issue from the BoothIQ app, which is emailed to your account's address and lives for a few minutes, and an offline master code from BoothIQ support for a booth with no internet. These are the one part of sign-in with a lockout: three wrong codes stop code entry for that username for fifteen minutes. How the codes are made and checked is on Emergency access, and the steps are in Get back into the admin area when you are locked out.

What the kiosk records

The sign-in screen's footer says that attempts are logged. Treat that modestly. The kiosk writes to log files on its own disk, and those files record password changes and every attempt with an emergency or master code; a routine sign-in, right or wrong, leaves no entry at all, and there is no sign-in history to look at in the admin area. The code attempts land in the debug log, which is kept for seven days, and the logs reach you only as a bundle requested from the app. Where the files live and how long they are kept is on Where the kiosk keeps its files and Customer data and privacy.

The locks, keys, and the room the booth stands in are the other half of the picture; see The booth in a public place.

Last verified against the software on 2026-10-25.